45+ Years Of Excellence Think Safety & Think Kusam-Meco
Digital Insulation Resistance Tester

KM887 Backlight Display- LCD

Model — KM887

Special Features :

Power Consumption: 6.5mA typical except the followings : VFD ACV : 8mAí Insulation Resistance @ 1mA Test Current : 50V output Voltage : 25mA, 100V output Voltage : 45mA 250V output Voltage : 85mA, 500V output Voltage : 170mA 1000V output Voltage : 440mA Tester can perform at least 950 Insulation…

  •   Dual Display +Hz readings.
  •   Safety : Double insulation per IEC / UL / EN61010
  •   1 Ed. 3.0, IEC / UL / EN61010
  •   030 Ed. 1.0, IEC / UL / EN61010
  •   033 Ed. 1.0,
  •   40.0 C to 0.0 C

Features

  • Dual Display +Hz readings.
  • Safety : Double insulation per IEC / UL / EN61010
  • 1 Ed. 3.0, IEC / UL / EN61010
  • 030 Ed. 1.0, IEC / UL / EN61010
  • 033 Ed. 1.0,
  • 40.0 C to 0.0 C
  • 40.0 F to 32.0 F

Specifications

General Specifications
DC Basic Accuracy 0.2% Sensing : AC, True RMSí Display : 3-5/6 digits 6000 Counts Backlight LCD Display.í Polarity : Automaticí Update Rate : 5 per second nominalí 61 Segments Bar Graph : 40 per second max.í Operating Temperature : -10ºC ~ 50ºCí Relative Humidity : Maximum relative humidity 90% for temperature í up to 28ºC decreasing linearly to 50% relative humidity at 50ºC. Pollution degree : 2í IP Rating Design : IP40í Storage Temperature : -20ºC ~ 60ºC, < 80% R.H. (with battery removed)í Altitude : Operating…
Safety Double insulation per IEC / UL / EN61010-1 Ed. 3.0, IEC / UL / EN61010-2-030 Ed. 1.0, IEC / UL / EN61010-2-033 Ed. 1.0, IEC / UL / EN61010-031 Ed. 1.1 & the corresponding CAN / CSA-C22.2 regulations to Measurement CAT III 1000V AC & DC & CAT IV 600V AC & DC. Compliance to IEC / EN61557:2007 : (per CE requirements, not certified by UL or ETL) : IEC / EN61557-1 & IEC / EN61557-2 .í Overload Protections : í Insulation Resistance, mA & mA : 0.4A/1KV, IR 30kA, F Fuse, or better A : 11A/1KV, IR 20kA,…

Overview

Power Consumption: 6.5mA typical except the followings : VFD ACV : 8mAí Insulation Resistance @ 1mA Test Current : 50V output Voltage : 25mA, 100V output Voltage : 45mA 250V output Voltage : 85mA, 500V output Voltage : 170mA 1000V output Voltage : 440mA Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature. These are standard tests of 1000V into 1MW with a duty cycle of 5 seconds on and 25 seconds off. Dimension: Approx. 208(L) X 103(W) X 64.5(H) mm with holsterí Weight: Approx. 635 gm with holster.í

Manuals, Catalogues & Software

Reviews & QA

No reviews yet for this product. Have a question about KM887 Backlight Display- LCD? Contact us and our team will get back to you shortly.

Send Enquiry