45+ Years Of Excellence Think Safety & Think Kusam-Meco
Digital Insulation Resistance Tester

KM878 Backlight LCD Display- Paper-White

Model — KM878

Special Features :

Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1W with a duty cycle of 5…

  •   Autoranging.
  •   Safety : Double insulation per IEC/UL/EN61010
  •   1 Ed. 3.0, IEC/EN61010
  •   030 Ed. 1.0,
  •   50.0ºC ~ 0.0ºC
  •   58.0ºF ~ 32.0ºF

Features

  • Autoranging.
  • Safety : Double insulation per IEC/UL/EN61010
  • 1 Ed. 3.0, IEC/EN61010
  • 030 Ed. 1.0,
  • 50.0ºC ~ 0.0ºC
  • 58.0ºF ~ 32.0ºF

Specifications

General Specifications
Sensing AC, True RMS Display : 3-5/6 digits 6000 Counts Backlight LCD Display.í Polarity : Automaticí Update Rate : 5 per second nominalí 61 Segments Analog Bar Graph : 60 per second max.í Power Supply: Four Alkaline AA batteriesí +Hz +Hz Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test o…
Safety Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC. Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL) : IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable.í E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,í EN61000-4-4, EN61000-4-5, EN61000-4-6…

Overview

Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1W with a duty cycle of 5 seconds on & 25 seconds off. Insulation Resistance @ 1mA Test Current : 50V output Voltage : 25mA, 100V output Voltage : 45mA 250V output Voltage : 85mA, 500V output Voltage : 170mA 1000V output Voltage : 440mA Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature. These are standard tests of 1000V into 1MW with a duty cycle of 5 seconds on and 25 seconds off. Operating Temperature : -10ºC ~ 40ºCí Relative Humidity : Maximum relative humidity 90% for temperature í up to 28ºC decreasing linearly to 50% relative humidity at 40ºC.

Manuals, Catalogues & Software

Reviews & QA

No reviews yet for this product. Have a question about KM878 Backlight LCD Display- Paper-White? Contact us and our team will get back to you shortly.

Send Enquiry