KM 1152MF Digital Multifunction Insulation Resistance
Resistance Testing, Polarisation Index measurement & Die electric Absorption ratio measure...
Special Features :
Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1W with a duty cycle of 5…
| Sensing | AC, True RMS Display : 3-5/6 digits 6000 Counts Backlight LCD Display.í Polarity : Automaticí Update Rate : 5 per second nominalí 61 Segments Analog Bar Graph : 60 per second max.í Power Supply: Four Alkaline AA batteriesí +Hz +Hz Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test o… |
|---|---|
| Safety | Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC. Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL) : IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable.í E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,í EN61000-4-4, EN61000-4-5, EN61000-4-6… |
Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mAí Earth Continuity Test : 110mA @20W range, 220mA @2.0W range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1W with a duty cycle of 5 seconds on & 25 seconds off. Insulation Resistance @ 1mA Test Current : 50V output Voltage : 25mA, 100V output Voltage : 45mA 250V output Voltage : 85mA, 500V output Voltage : 170mA 1000V output Voltage : 440mA Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature. These are standard tests of 1000V into 1MW with a duty cycle of 5 seconds on and 25 seconds off. Operating Temperature : -10ºC ~ 40ºCí Relative Humidity : Maximum relative humidity 90% for temperature í up to 28ºC decreasing linearly to 50% relative humidity at 40ºC.
No reviews yet for this product. Have a question about KM878 Backlight LCD Display- Paper-White? Contact us and our team will get back to you shortly.