Special Features :

When testing insulation resistance while there is a presence of voltage (whether ACV or DCV) on the measured object, conventional insulation testers are highly susceptible to damage. With this new line of insulation testers, it has the ability to switch to voltage detection mode without damaging…

  •   Test voltage : From 500Vdc to 15kVdc
  •   Preset buttons : 1kV, 5kV, 10kV, 15kV
  •   Insulation resistance :1000GΩ/0.5kV
  •   Accuracy : 1kV: 0~200GΩ
  •   Resolution : 1GΩ : 0.001GΩ
  •   Short circuit current :up to 5mA

Features

  • Test voltage : From 500Vdc to 15kVdc
  • Preset buttons : 1kV, 5kV, 10kV, 15kV
  • Insulation resistance :1000GΩ/0.5kV
  • Accuracy : 1kV: 0~200GΩ
  • Resolution : 1GΩ : 0.001GΩ
  • Short circuit current :up to 5mA
  • PI (Polarization Index) : yes
  • DAR (Dielectric Absorption Ratio) : Yes
  • Voltmeter : ACV : 30~600V (50/60Hz)
  • Current :
  • Measurement :
  • Power source : Rechargeable battery
  • Adapter : Input : 100
  • 240Vac, 0.4A, 50
  • 60Hz
  • Dimensions : 430(L) x 324(W) x 127(D)mm
  • Weight : Approx : 6.56kg
  • Downloading saved data to a PC.
  • Transferring and showing real
  • time data to a PC.
  • 200 measurement results can be saved in the

Specifications

AC / DC Voltage 600V. - PI & DAR indication. - Auto-ranging on all insulation ranges. - 2 Lines X 16 Characters large LCD Backlight display. - Bargraph indicates test Voltage, rise & decay can be observed. - Visual & audible warning if external voltage is present. ( 30Vac or 30Vdc) - Auto-hold function to freeze the reading. - Overload Protection
Adjustment for testing time (duration) 1 ~ 30 minutes - Auto-off. - Calendar - Optical USB to RS-232 data transmission. - 200 measurement results can be saved in the memory & recalled on the display.
Safety Standard EN61010-1 CAT IV 600V EN61010-2-030; EN61326-1
Test voltage From 500Vdc to 15kVdc Adjustable in 500V steps
Preset buttons 1kV, 5kV, 10kV, 15kV
Insulation resistance 1000GΩ/0.5kV 1000GΩ at 0.5kV ~ 30TΩ at 15kV
Accuracy 1kV: 0~200GΩ 5kV: 0~1TΩ 10kV: 0~2TΩ 15kV: 0~3TΩ ±(5%rdg+5dgt) 1kV: 200GΩ~2TΩ 5kV: 1TΩ~10TΩ 10kV: 2TΩ~20TΩ 15kV: 3TΩ~30TΩ ±20%
Resolution 1GΩ : 0.001GΩ 10GΩ : 0.01GΩ 100GΩ : 0.1GΩ 1000GΩ : 1GΩ 10TΩ : 10GΩ 30TΩ : 100GΩ
Short circuit current up to 5mA
PI (Polarization Index) yes
DAR (Dielectric Absorption Ratio) Yes
Voltmeter ACV : 30~600V (50/60Hz)
Power source Rechargeable battery
Adapter Input : 100-240Vac, 0.4A, 50-60Hz Output : 24Vdc, 0.62A
Dimensions 430(L) x 324(W) x 127(D)mm
Weight Approx : 6.56kg Data Communication Function — Downloading saved data to a PC. — Transferring and showing real-time data to a PC. — 200 measurement results can be saved in the memory and recalled on the display. Measure the insulation of cable Accessories

Overview

When testing insulation resistance while there is a presence of voltage (whether ACV or DCV) on the measured object, conventional insulation testers are highly susceptible to damage. With this new line of insulation testers, it has the ability to switch to voltage detection mode without damaging the instrument once it detects the presence of voltage. It will also display the voltage finding on the LCD screen. With this new and unique function, it will allow the user to safely rule out the possibility of any presence of voltage on the measured object prior to measuring