KM 031 AmpTip low-current range calibrated at
DCA and ACA Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 40 d...
Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23C ± 5C Maximum Crest Factor <2 :1 at full scale & <4:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms. AC VOLTAGE…
| Sensing | True RMS |
|---|---|
| Jaws Opening size | 26mm Max. |
| Display | 3-5/6 digits 6000 counts Update Rate : 5 per second nominalí Polarity : Automaticí Operating Temperature : 0ºC to 40ºCí Relative Humidity : Maximum relative humidity í 80% for temperature up to 31ºC decreasing linearly to 50% relative humidity at 40ºC Altitude : Operating below 2000mí Storage Temperature : -20°C ~ 60°C, í <80% R.H. (with battery removed) |
| Safety | Certified per IEC/EN/CSA_C22.2_No./UL standards: 61010-1 Ed. 3.1, 61010-2-032 Ed. 4.0, & 61010-031 Ed. 2.0 to Measurement Categories CAT III 600V and CATIV 300V AC & DC Overload Protection :- Current via jaws : 200A DC / AC rms at <400Hz. Voltage via terminal: 660V DC / 1100VAC rms. Other functions via terminals : 600V DC / AC rms Pollution Degree : 2- Rugged Fire retarded housing.- Transient Protection : 6.0kV (1.2/50ms surge)- ACCESSORIES : Test leads set, Users Manual, Bkp60 banana plug type… |
| Temperature Coefficient | Nominal 0.1 x o o o (specified accuracy) / C @ (0C -- 18C or o o 28C -- 40C), or otherwise specified Power Supply : Standard 1.5V AAA Size Battery X 2í Power Consumption : typical 13mAí Low Battery — : Below approx. 2.85V for Capacitance & Hz. Below 2.5V for other functions APO timing : Idle for 32 minutesí APO Consumption : typical 5mAí Dimension : 188(L) x 66(W) x 32(H)mmí Weight : approx 202 gms.í |
| E.M.C. | Meets EN61326-1 DCA and ACA Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 40 digits at around 87MHz DCmA & Ohm Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 25 digits Other Functions, in an RF field of 3V/m : Total Accuracy = Specified Accuracy + 20 digits LVD - Certified EN61010-2-032, EN61010-1 & Relevant Standards On |
Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23C ± 5C Maximum Crest Factor <2 :1 at full scale & <4:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms. AC VOLTAGE (Low-Pass Filter (LPF)) Input Impedance : 10MW, 100pF nominal Range Accuracy Resolution
No reviews yet for this product. Have a question about KM 137MA AmpTip low-current range.? Contact us and our team will get back to you shortly.