KM 66 & KM 69 Voltage Tester
Special Features :
RST 3-Phase Rotation Detection (KM69) Voltage Rage : 165V ~ 1000V Frequency Range : 45Hz~ 65Hz Applications : Intended for Y-Connection 3P4W & High-leg D-Connection 3P3W System. Not Intended for D-Connection 3P3W System without an earth-ground neutral. LED Threshold ON : < 85% of Voltage Marking.…
- Detection
- LCD Indication (KM 69)
- Handy & Stylish, Fits Comfortably in one's hand
- 19mm Probe Pitch For Quick European Receptacle Testing
- 4mm Test Tips with IP2X Retractable shroud for IEC61243
- 3 Ed3
Features
- Detection
- LCD Indication (KM 69)
- Handy & Stylish, Fits Comfortably in one's hand
- 19mm Probe Pitch For Quick European Receptacle Testing
- 4mm Test Tips with IP2X Retractable shroud for IEC61243
- 3 Ed3
- Detachable (Black) test lead for easy replacement.
- User Replaceable Screw
- On stationary (Red) Probe Body
- Battery
- less ELV Limit (120VDC/50VAC) LED Indication
- less DCV & ACV Auto
- selection with LED polarity indication
- less DCV 8
- Ranges LED Indication : 12, 24, ... to 1000V
- less ACV 8
- Automatic Power On & Power Off
- contact EF
- Detection (NCV)
- Probe contact EF
- Detection for more precise indication of live
- Continuity : Audible beeper & visible LED indications
- Display Backlight & flash
- light for easy viewing in the dark (KM 69)
- True RMS ACV Reading on LCD Numeric Display (KM 69)
- Detection Shaker indicates ACV is being measured (KM 69)
- RCD Leakage Load for 230V AC / 30mA RCD Circuit Breakers (KM 69)
- RST Phase sequence / Rotation indication (KM 69)
- Low Battery warning for battery operated functions & features
- Battery Access Door
- LCD Display : 1999 counts (KM 69)3½ Digits
Specifications
| Battery-less DCV 8-Ranges LED Indication | 12, 24, ... to 1000V |
|---|---|
| Battery-less ACV 8-Ranges LED Indication | 12, 24, ... to 1000V — Automatic Power On & Power Off — Non-contact EF-Detection (NCV) — Probe contact EF-Detection for more precise indication of live |
| Continuity | Audible beeper & visible LED indications — Display Backlight & flash-light for easy viewing in the dark (KM 69) — True RMS ACV Reading on LCD Numeric Display (KM 69) — AC-Detection Shaker indicates ACV is being measured (KM 69) — RCD Leakage Load for 230V AC / 30mA RCD Circuit Breakers (KM 69) — RST Phase sequence / Rotation indication (KM 69) — Low Battery warning for battery operated functions & features — Battery Access Door |
| Meets IEC/EN61010-1Ed. 3.0, IEC/EN61010-2-033Ed. 1.0, IEC/EN61243-3 | 2014 to CAT III 1000V & CAT IV 600V |
|---|---|
| Transient Protection | 8kV lightning surge (1.2/50µs) |
| Measurement Category | CAT III 1000V & CAT IV 600V AC & DC |
| Overload Protection | 1100VDC & VAC rms |
| Type of Protection | IP65 Per EN60529 - water and Dust Resistant. — Rugged fire retarded double injected casing |
| E. M. C. | Meets EN61326-1:2013 For LCD display only : (KM69) Total Accuracy = Specified accuracy + 45d @ an RF field of 3V/m. |
Overview
RST 3-Phase Rotation Detection (KM69) Voltage Rage : 165V ~ 1000V Frequency Range : 45Hz~ 65Hz Applications : Intended for Y-Connection 3P4W & High-leg D-Connection 3P3W System. Not Intended for D-Connection 3P3W System without an earth-ground neutral. LED Threshold ON : < 85% of Voltage Marking. LED Threshold OFF : > 110% of pre-voltage Marking. Input Impedance : 12V, 24V, 50V Voltage Markings : 100KW, 160pF nominal. 120V, 230V, 400V, 690V, 1000V Voltage Marking : 200KW ~ 500KW vary linearly, 160pF nominal ACV Frequency Responses : 45Hz ~ 65Hz Duty ratio : Continuous @ £ 300V Time rating (t) ON for 30 seconds & recovery time (r) OFF for 2 minutes@ > 300V Open Circuit Voltage : 0.7 DC Typical Audible Threshold : between 500KW and 750KW kusamelectrical.comE-mail : Website : www. sales@kusam-meco.co.inAn ISO 9001:2015 Company
Manuals, Catalogues & Software
Reviews & QA
No reviews yet for this product. Have a question about KM 66 & KM 69 Voltage Tester? Contact us and our team will get back to you shortly.