The KM 071 Milliamp Process Clamp Meter is a Hand-held battery
The KM 071 Milliamp Process Clamp Meter is a Hand-held battery operated clamp meter that m...
KM 4002-1000A True RMS Digital Clamp Meter are 6000-count digital clamp meters with auto range, large LCD, true RMS, autoscale memory, and NCV functions. They conform to CAT III 1000V/CAT IV 600V safety rating and certified by CE / ETL. KM 4002 come with LoZ mode for eliminating 'ghost 'voltage…
| Jaw opening | 42mm — Zero Mode Function |
|---|---|
| Sensing | AC True RMS |
| Sensor type | Coil induction |
| Display | 6000 Counts display |
| Display Size | 43 x 45mm |
| Jaw opening | 42mm |
| Polaritydisplay | Auto |
| Sampling rate | 3 times/s |
| Overload display | "OL" or "-OL" |
| Low battery indication | " " is displayed. |
| Test position error | If the source under test is not placed at the |
| Power Supply | 1.5V AAA x 3 batteries. |
| Weight | Approx. 492gms. |
| Dimension | Approx.272(W) x 81(H) x 43.5(D)mm AC Current ( ) Range AccuracyResolution 60.00A ± (2.0%+9)0.01A 600.0A 1000A ± (2.0%+5) 0.1A 1A |
| Overload Protection | 1000V DC/AC |
| Display | True RMS |
| Accuracy | 5%~100% of range. Open circuit allows least significant digit ≤10. |
| Frequency response | 40Hz~400Hz — The AC crest factor will reach 3.0 at 3000 counts while only reach ≤1.5 at 6000 counts. The additional error should be added according to the crest factor of a non-sinusoidal wave are : a) Add 4% when crest factor is 1~2 b) Add 5% when crest factor is 2~2.5 c) Add 7% when crest factor is 2.5~3 — For current frequency monitoring, the resolution is 0.1Hz and accuracy is ± (0.1%+3). The input amplitude should be ≥10% of range. Range 60.00A 600.0A 1000A 30.00A 300.0A 3000A Resolution 0… |
| Overload Protection | 1000V |
| Accuracy | 5%~100% of range. Short circuit allows least significant digit ≤5. |
| Input impedance | About ≥10MΩ |
| Frequency response | 40Hz~400Hz — The AC crest factor will reach 3.0 at 3000 counts while only reach ≤1.5 at 6000 counts. The additional error should be added according to the crest factor of a non-sinusoidal wave as follows: a) Add 4% when crest factor is 1~2 b) Add 5% when crest factor is 2~2.5 c) Add 7% when crest factor is 2.5~3 — For voltage frequency monitoring, the resolution is 0.1Hz and accuracy is ± (0.1%+3). The input amplitude should be ≥10% of range. DC Current ( ) Range AccuracyResolution 60.00A ± (2.… |
| Accuracy | 5%~100% of range. — Press the REL ZERO button to remove any DC offset that could affect the accuracy of reading. LoZ V~ |
| Input impedance | About 2kΩ |
| Frequency response | 40Hz~400Hz — The AC crest factor will reach 3.0 at 3000 counts while only reach ≤1.5 at 6000 counts. The additional error should be added according to the crest factor of a non-sinusoidal wave as follows: a) Add 4% when crest factor is 1~2 b) Add 5% when crest factor is 2~2.5 c) Add 7% when crest factor is 2.5~3 — When the measured voltage is above 220V, the continuous measurement time cannot exceed 30s and the rest interval should be more than 30s. — For voltage frequency monitoring, the resol… |
| Frequency response | 40Hz~200Hz — The AC crest factor will reach 3.0 at 3000 counts while only reach ≤1.5 at 6000 counts. The additional error should be added according to the crest factor of a non-sinusoidal wave as follows: a) Add 4% when crest factor is 1~2 b) Add 5% when crest factor is 2~2.5 c) Add 7% when crest factor is 2.5~3 — The -3dB frequency of LPF is about 2.5kHz Only manual range for LPF ACV. Use the RANGE button to change the range. — For voltage frequency monitoring, the resolution is 0.1Hz and accu… |
KM 4002-1000A True RMS Digital Clamp Meter are 6000-count digital clamp meters with auto range, large LCD, true RMS, autoscale memory, and NCV functions. They conform to CAT III 1000V/CAT IV 600V safety rating and certified by CE / ETL. KM 4002 come with LoZ mode for eliminating 'ghost 'voltage, LPF ACV function for measuring INV and VFD voltage, and inrush current mode for capturing transient current. The KM 4002 also feature high-precision temperature measurement with 0.1 °C resolution, and can be equipped with a flexible current probe to extend the AC current measurement range to 3000A. Flashlight button: Short press this button to turn on/off the flashlight.