KM 2006
KM 2006 Digital Leakage Current Clampmeter
Standards Applied : IEC/EN 61010-1:2010 (3 Edition); IEC/EN 61010-2-032:2002 (2 Edition) T...
Leakage Current
| Function | Measurement of AC Leakage current, AC Current & on-line AC current. |
|---|---|
| Test Mode | Clamp CT, integration method |
| Display mode | 4 digits LCD display |
| CT Size | F40mm |
| LCD Dimension | 35 x 21.5 mm |
| Display Size | 32 x 15mm |
| Sampling rate | about 2 times/s |
| Frequency | Automatic identification 50Hz / 60Hz |
| Shift | Automatically |
| Line Voltage | Line measurement below AC 600V |
| Data Storage | its, flashing display "FULL" symbol indicate storage full.99 un |
| Peak Hold | Peak capture & Hold function, long press key & not release can display peak value in measurement. |
| Data Hold | Data hold function : symbol display. |
| Overflow display | Over range overflow function symbol display. |
| Working Current | 5mA |
| Operating Temperature | 0°C ~ 40°C, Below 80% RH |
| Storage Temperature | ~ 60°C, Below 80% RH -10°C |
| Insulating Strength | AC 2KV / rms (between the core & outside shell) |
| Automatic shutdown | 5 minutes after power on, the meter shuts down automatically without any operation to reduce battery consumption. |
| Battery Voltage | While battery voltage drop to around will display 2.82V, low battery voltage " " , & remind to replace the battery. |
| Power Supply | Alkaline dry battery LR03 x 2 |
| Dimension | Approx. 180 x 72 x 32mm |
| Weight | Approx. 0.31kg (including accessories) |
| Safety | IEC1010-1, IEC1010-2-032, Pollution 2, CAT III (600V) |
| Accessories | User manual, battery & carrying case. |